Medical Plant Growth Chamber - Astra Scientific
Medical Plant Growth Chamber
ASTRA SCIENTIFIC Product Name: Medical Plant Growth Chamber
ASTRA SCIENTIFIC Product Code: ASTRALAB-SUPPLYA10004

Description and Specification for Lab Tenders

Medical Plant Growth Chamber.

The plant growth chamber is equipped with visible light and near-ultraviolet lamps, which can independently control the type of light source, and can print and record visible light and near-ultraviolet irradiance in real time; visible light and near-ultraviolet can be directly set, automatically adjusted, and precisely controlled.
Internal volume: 150L~800L
Temperature control range: 15~50℃, temperature control fluctuation: ±0.5℃, temperature deviation: ±2.0℃ (same level);
Illumination range: Visible light range: 100~8000LUX; the total illuminance is not less than 1.2×106Lux·hr;
Ultraviolet range: Near ultraviolet range: 0.84~5w/m²; near ultraviolet energy is not less than 200w•hr/m²;
Ultraviolet wavelength: Near ultraviolet wavelength: 320~400nm;
Illumination control: The three parameters of temperature, visible light, and near ultraviolet are directly set and controlled on the controller;
Illumination printing: It can print three values of temperature, visible light and near ultraviolet at the same time;
Three kinds of controllers: original imported temperature controller, original imported visible light controller, original imported near ultraviolet controller;
Illuminance sensor: equipped with visible light sensor and near ultraviolet sensor;
Refrigeration compressor: Original imported fully enclosed compressor, long life, low noise;
Data printing: temperature value, visible light value and near ultraviolet value can be printed;
Data storage: It can store temperature values, visible light values, and near ultraviolet values for more than 1 year;
On-site alarm: On-site temperature deviation sound and light alarm, independent over-temperature alarm;
Box material: The inner tank is made of mirror stainless steel 304, and the outer shell is made of high-quality steel plate sprayed with plastic;
Dual protection: Configure an anti-over-temperature protection system; configure an independent over-temperature protection system, which can automatically cut off the power supply;
Safety devices: compressor overheat protection, compressor overpressure protection, compressor overload protection and fan overheat protection;
Remote alarm: Optional remote SMS alarm (with power failure alarm), multiple devices can share a mobile phone card
Installation power supply: AC 220V±10% 50HZ;
Working environment: +5~35℃ (best to be controlled within 30℃, and within 26℃ under extreme conditions);